Voltage current meter Power capacity Owatrous voltage Overvoltage Protects Multifunctional battery charging discharge control UI5
Solemnly declare:Most of our new products have made the appearance patent, and they must not be sold without authorization.IntersectionOur company will not report them one by one, and only multiple products will be reported together, which will cause you the loss of the store to be closed. Our company will not bear the responsibility!IntersectionIntersection
The patent has been applied, and the imitation must be investigated!IntersectionIntersection
Multifunctional voltage current meter (power, capacity, time, charging and discharge, up voltage, overvoltage, overcurrent protection, etc.)
Please read the instructions carefully before use, the manual download address:
http://www.qingdaowuzhi.com/download/17254.html?a=download
1. Product bright spots
·The measurement circuit is required from the power input port, and there is no need to power the power line.
·Use LCD screens to display information such as voltage, current, power, discharge MAH, discharge time and working temperature.
·The protection mechanism is complete, and there are many protection such as under pressure protection, overvoltage protection, overcurrent protection, over -power protection, over -temperature protection, over time protection, and ultra -capacity.
·By setting the appropriate pressure protection and overvoltage protection threshold, the battery can be overcharged and over -release control function.
·By setting the appropriate timeout protection and ultra -capacity protection threshold, a fixed and quantitative battery filling and discharge can be achieved.
2.Product parameters
3.Product Description
3.1 Detailed product function
1. LCD screen display
Under normal mode, the uplink of the LCD screen shows the input voltage and operating temperature; the downlink shows the real -time current, power, capacity, and discharge time.
In the protection mode, the LCD screen shows the protection code.
In the setting mode, the LCD screen displays each settings parameter code and parameter threshold.
2. Sound and light alarm
When the output of the voltage current is turned on, the RUN indicator light is often on, and the bee tweee does not sound; when it is turned off, the RUN indicator is not bright, and the bee twiser does not sound.After entering the protection mode, the bee twitters of the bee twitter called the police, and the Run indicator flickered.
3. Automatic statistics of the charging and discharge capacity and time. As long as the output (Run indicator light is always on), start statistics, turn off the output (the Run indicator is not bright), stop the statistics, the power loss statistics are automatically cleared, and the display capacity and time are displayed.During the interface, long press the button—You can clear the corresponding data.Before starting statistics, please clear the statistics.The maximum discharge capacity (OAH) and maximum discharge time (OHP) can be set to open or close (default shutdown) in the setting mode. After opening, you can set the threshold size, exceed the threshold, the output is automatically closed, and the beeurizer alarm to achieve no realization.Human -to -person battery is charged and discharged.
4. By setting the appropriate overvoltage protection threshold and the underwriting pressure protection threshold, the battery can be overcharged and overlap.For more detailed operation, please refer to the example of product application.
5. Perfect software and hardware protection mechanism, and software protection thresholds can be adjusted.After the software is protected, the output is turned off.
Hardware protection:
The module input port has anti -anti -connection protection, and the counter -connection is not burned.
Software protection:
OVP overvoltage protection (default 38V, you can set itself. After the overvoltage protection, the Run indicator lights flickered, and the liquid crystal interface displays OVP. In the battery charging, set the appropriate threshold to effectively prevent the battery from being charged);
OCP overcurrent protection (default 5.5A, you can set it by yourself, after the overcurrent protection, the Run indicator flickering, LCD display OCP);
OPP is too power protection (the default is 200W, you can set it by yourself. After the power protection, the RUN indicator flickered, the LCD display OPP);
OTP over -temperature protection (default 80 ° C, you can set it by yourself. After the temperature is protected, the Run indicator lights flickering, the LCD display OTP);
LVP under pressure protection (default 4.8V, you can set it by yourself. After the underwriting protection, the Run indicator lights, LCD display LVP, and set the appropriate LVP in battery discharge testing and other applications to effectively prevent the battery from excessive discharge, so as not to damage the battery.
6. The voltage current output is turned on by default.
7. All parameters support the power loss storage.
3.2 Press the detailed explanation 3.3 Detailed explanation of the product interface
1. Normal mode interface
Note: Press the button SW, you can switch the display of the current, power, discharge capacity, and discharge time of the display screen; long -press button SW, you can switch the display of the uplink voltage and temperature of the display screen.The output opening will display OUT, and the output is not displayed without display. 3.3 Detailed explanation of the product interface
1. Normal mode interface
Note: Press the button SW, you can switch the display of the current, power, discharge capacity, and discharge time of the display screen; long -press button SW, you can switch the display of the uplink voltage and temperature of the display screen.The output opening will display OUT, and the output is not displayed without display. 3. Set the mode interface
Note: In normal mode, long press the button on and enter the setting mode.In setting mode, long press the button on and enter the normal mode.
Under the setting interface, press the key SW to switch the parameters that need to be set.Short button+or-, adjust the parameter size.Display timeout or ultra -capacity interface, short press the keys on, and select or turn off the timeout or over -capacity protection.They are closed by default.
3.3 Product application detailed explanation
1. General voltage, current, and power table use, string can be entered.
2. Battery charging application, as follows:
Steps for usage:
1. First follow the power module and battery according to the above figure, and check whether the wiring is correct.
2. Power power, enter the normal interface as shown above.
3. Long press the ON key and enter the setting interface. The lower left corner of the LCD screen displays set.
4. Press the SW key and switch the parameters that need to be set.Short press+or-, add 1 or minus 1 by parameters.Long press+or-, make the parameters continuously
Add or decrease continuously.In the battery charging application, the LVP needs to be adjusted below the minimum voltage of the battery, the minimum is 4.8V.
To the battery, the maximum voltage is allowed to be fully charged (this voltage needs to refer to the parameters in the battery manual).General 12V electrical battery
The highest charging voltage of the pool is 14V. Generally, the maximum charging voltage of the lithium battery of 24V is 28V.
5. Long press the on key and exit the setting mode.
6. Press the on key, the indicator light is often on, turn on the output, and the battery begins to charge.
7. If the battery voltage rises to the value of OVP settings, the output is turned off, the battery stops charging, the LCD screen displays OVP, indicating
The lights flickered, and the beekee called the police.
8. If you need to charging regularly or fixed capacity, you can set OHP (time) or OAP (fixed capacity) in the setting mode
parameter.Setting steps: Under the setting interface, press the SW key to switch to the OHP or OAH interface.Short press the on key, turn on time or
Determine the capacity function, the downlink down of the liquid crystal interface changes from OFF to numbers.Press+or-key to adjust the parameter size.After setting the parameter,
Long press the ON key Exit the setting interface.When the time or the capacity reaches the set value, the output is turned off to stop charging, and the LCD screen is displayed
Show OHP or OAP code, the indicator lights are flickering, and the bee tweeper calls the police.
3. Battery discharge application, as follows:
Steps for usage:
1. Put the battery and load according to the above figure, and check whether the wiring is correct.
2. The voltage current meter enters the normal interface.
3. Long press the ON key and enter the setting interface. The lower left corner of the LCD screen displays set.
4. Press the SW key and switch the parameters that need to be set.Short press+or-, add 1 or minus 1 by parameters.Long press++
Or-can make parameters continuously or continuously.In the battery discharge application, OVP needs to be adjusted to the battery most
Above a high voltage, the highest is 38V.Adjust the LVP to the minimum voltage allowed by the battery (this voltage needs to be refused
Parameters in the battery instructions).Generally, the minimum discharge voltage of the lithium battery of 12V is 9.2V.24V
The minimum discharge voltage of the lithium battery is 18.5V.
5. Long press the on key and exit the setting mode.
6. Press the on key, the indicator light is often on, the output is turned on, and the battery begins to discharge.
7. If the battery voltage drops to the value of LVP settings, the output is turned off, the battery stops discharge, LCD
The screen displays the LVP, the indicator lights are flickering, and the bee tweeper calls the police.
8. If you need to discharge regularly or set the capacity discharge, you can set OHP in the setting mode (timing)
Or OAP (fixed capacity) parameters.Setting steps: Under the setting interface, press the SW key to switch to OHP
Or OAH interface.Press the ON key to open the fixed or fixed capacity function.
Make numbers.Press+or-key to adjust the parameter size.After setting the parameters, press the on key to exit the settings
interface.When the time or capacity reaches the set value, the output is turned off to stop discharge, and the LCD screen display
OHP or OAP code, the indicator lights flickered, and the beeurizer calls the police.